EMAQ ASSESSMENT REPORTS

COMMERCIAL KITCHEN VENTILATION REPORTS

CONTROL OF ODOUR, SMOKE & NOISE FOR COMMERCIAL KITCHENS

Arrow Down
EMAQ report document. for commercial kitchen smoke, odour and noise abatement

Are you currently going through a change of use?

Smoke, Odour & Noise Control Reports For Commercial Kitchen Ventilation Systems & Ducting

 ‘Risk Assessment for Odour’ has been derived from criteria outlined by DEFRA 2005, Guidance on the Control of Odour and Noise from Commercial Kitchen Exhaust Systems Appendix C, which was subsequently updated by EMAQ in 2018. Odour control must be designed to prevent odour nuisance in a given situation. The following score methodology is suggested as a means of determining odour control requirements using a simple risk assessment approach. Which will conduct within your report

All our systems are designed to DW172 Regulations

Council Planning :

✔️ Design Of System

✔️  Smoke Abatement Solutions

✔️  Odour Abatement Solutions

✔️  Noise Abatement Solutions

✔️  Guaranteed Council Approval with our specialist planning and design for commercial kitchens

SOLUTIONS FOR ALL TYPES OF COMMERCIAL KITCHEN ODOUR CONTROL

Cost Effective Odour Control Solution For Commercial Kitchens

Odour Control for  commercial kitchens & commercial kitchen ventilation

When it comes to managing and controlling the odours within a commercial kitchen there are numerous options available. 

Option 1

Ozone Generators

These electrical units work by generating O3, been specifically designed for use in commercial kitchens.

The system injects ozone into the kitchen extraction canopy or associated duct work where it reacts with odours, which are oxidized in a chemical reaction, which results in the production of carbon dioxide and water vapour.

 

The ozone itself is consumed during the process and is converted back into oxygen.

Incorporating make up air into the front face of the canopy allows a perfect solution for working with gas appliances to efficiently and effectively become compliant to gas safe regulations. We can also add spot coolers to allow controlled air flow to improve working conditions along the cookline for chefs

Advantages

✔️ Can be retrofit

✔️ Requires minimal maintenance

✔️ Cant be installed at head height termination

✔️ Works on smaller kitchens

✔️ Accepted by all councils

Disadvantages

✔️ Don't always work well in larger kitchens

commercial kitchen ozone generator. showing how they work connected to ducting

Innovative Solutions for Odour Control

Option 2

Carbon Filtration

Carbon filtration is ideal for removing unpleasant or even dangerous odours and gases from a wide variety of sources.

The ever increasing awareness of this problem from public health authorities and environmentalists has resulted in an increase in the use of the unique properties of activated carbon filtration.

 

Carbon will adsorb chemical molecules in the airstream in varying degrees according to the type of contaminant and the period of time the air remains resident in the carbon.

Activated Carbon in its loose granular form can present problems as there is a tendency to for the granules to abrade one another. This causes both settlement of the carbon creating potential bypass voids and produces carbon dust that can be re-entered into the air-stream.

 

The unique bonding method eradicates these problems by producing a solid and stable biscuit of consistent quality and dimensional stability that produces an even resistance. Once formed the biscuits are bonded in ‘V’ formation into a rigid galvanised steel casing.

Advantages

✔️ Can be retrofit

✔️ Works on all kitchen sizes

✔️ Highly Effective

Disadvantages

✔️ Heavy To Lift

✔️ Can be expensive to replace

✔️ Fans may need upgrading

SOLUTIONS FOR ALL TYPES OF COMMERCIAL KITCHEN SMOKE CONTROL

Advanced Smoke Control Solutions for Commercial Kitchens

Smoke Control for  commercial kitchens & commercial kitchen ventilation

ESP - Electrostatic Precipatator

Electrostatic  Precipitators  or  ESPs  work  by  ionizing  and  trapping  grease  and  smoke  particles  onto  collector  plates. 

They  have  a  high  particulate  removal  efficiency,  removing  sub-­‐micron  particles  as  much  as  99.5%.  Exhaust  air  flows  through  two  sets  of  ionizer  cells  and  collector  plates  to  ensure  maximum  efficiency. 

 

A  significant  advantage  of  ESPs  is  the  low  pressure  drop  which  means  that  existing  fans  do  not  need  to  be  upgraded.

Advantages

✔️Can be retro fit

✔️ Fan upgrades not always requried

✔️ Highly Effective

✔️ Suitable for all applications

Disadvantages

✔️ Quite large in size

✔️ Require external power source

SOLUTIONS FOR ALL TYPES OF COMMERCIAL KITCHEN NOISE CONTROL

How Premier Catering Manufacture Reduces Kitchen Noise

Noise Control for  commercial kitchens & commercial kitchen ventilation

Reducing noises generated from commercial kitchen fans can be achieved in numerous ways. Typically the ideal decibel reading required by councils in 50db. Most high performance fans do not achieve this before they are installed. 

The options are dependant on where the breakout is required is done by installing silencers

1D Silencer - Typically reduces by 7-10db at termination breakout

2D Silencer - Typically reduces by 10-14db at termination breakout

Pod silencers - available in 1D & 2D offer improved DB reductions by the insertion of a pod dish these improvements can see anywhere from 140-21db at termination breakout

Acoustic Lagging - provides an external wrap of ducting and fans and can provide huge reductions from 33db

Available for all duct & fan sizes